CA-IS1300B25G
Active
Full-differential Isolated Amplifier
The CA-IS1300x devices are high-precision isolated amplifiers and optimized for shunt-resistor-based current sensing. Low offset and gain error and drift guarantee that measuring accuracy is maintained over the entire operating temperature range.
The CA-IS1300x devices utilize silicon oxide (SiO2) isolation barriers and support up to 5-kVRMS galvanic isolation per UL 1577. This technology separates high- and low-voltage domain to protect lower-voltage parts from damage and provides low emissions as well as strong anti-interference capability from magnetic changes. The high common-mode transient immunity (CMTI) means that the CA-IS1300x devices transmit correct signals through isolation barriers and are suitable for industrial motor controls and drives which require high-voltage and high-power switching. The internal input common-mode overvoltage and missing highside supply voltage detection functions contribute to fault diagnostics and system safety.
The CA-IS1300x series provide two input voltage range options and the smaller rank (±50 mV) allows significant reduction of the power dissipation through the shunt resistor.
The CA-IS1300x devices are packaged in wide body, 8-pin SOIC packages and specified over the extended industrial temperature range of –40°C to 125°C.
-
Features
Differential Input Voltage Range
±50 mV or ±250 mV
Fixed Initial Gain
8.2 or 41
Low Input Offset and Drift
CA-IS1300G05: ±0.1 mV (max) at 25°C, ±1 μV/°C(max)
CA-IS1300G25: ±1 mV (max) at 25°C, ±4 μV/°C(max)
CA-IS1300B25: ±0.2 mV (max) at 25°C, ±4 μV/°C(max)Low Gain Error and Drift
CA-IS1300G05: ±0.3% (max) at 25°C, ±50 ppm/°C(max)
CA-IS1300G25: ±0.5% (max) at 25°C, ±50 ppm/°C(max)
CA-IS1300B25: ±0.3% (max) at 25°C, ±50 ppm/°C(max)Low Nonlinearity and Drift
0.01% (typ) for Full Scale, ±1 ppm/°C (typ)
3.3-V or 5-V Operation for Both High- and Low-Side
High CMTI
±150 kV/µs (typ)
Wide Operating Temperature Range
–40°C to 125°C
Safety-Related Certifications
7070-VPK Isolation per DIN EN IEC 60747-17 (VDE 0884-17)
5-kVRMS Isolation for 1 Minute per UL 1577
TUV Certification Approvals>40-year Life at Rated Working Voltage
-
Applications
-
Industrial Motor Controls and Drives
-
Isolated Switch Mode Supplies
-
Uninterruptible Power Supplies
-
-
Device Information
PART NUMBER PACKAGE BODY SIZE (NOM) CA-IS1300x SOIC8-WB (G) 5.85 mm × 7.50 mm -
Simplified Functional Diagram
-
Technical Documentation
Category
Title
Last Updated
-
Title: Datasheet
Last Updated: Nov 21,2023
-
Title: APPNOTE
Last Updated: Feb 21,2023
-
Title: APPNOTE
Last Updated: Feb 21,2023
-
-
Certification Standards
Category
Title
Certification Number
Date
-
Title: CQC
Certification Number: CQC24001434134
Date: Jun 06,2024
-
Title: Reliability Test
Certification Number: CA-IS12XX & CA-IS13XX
Date: Jul 06,2022
-
Title: VDE
Certification Number: 40057278
Date: Aug 21,2023
-
Title: UL
Certification Number: UL-US-L511334-11- 02500202-5
Date: Apr 12,2023
-